Update server and choice firmware the use of HP SUM on HP Proliant ML10 v2.
Update Server Firmware. Before we keep to put in Windows Operating System on HP Proliant ML10 V2 server, we have to replace the firmware to the ultra-modern version. Therefore we need unique software from HP, this software is called HP Service Pack for ProLiant (SPP), SPP is a packaging and collection made of firmware, drivers and Smart Components for HP ProLiant Servers & Blades Infrastructure.
This is an optionally available alternative you can do, before putting in home windows server 2012 R2 on your HP Proliant ML10 V2 server. Once HP Service Pack for ProLiant (SPP) is load with the aid of your server, you can pick two option to replace the firmware on P Proliant ML10 V2 server, that options are Automatic Firmware Update Version 2015.10.0 and Interactive Firmware Update Version 2015.10.0. For beginner person, we recommended which you pick out Automatic Firmware Update Version 2015.10.Zero. Ok, now comply with this education below to replace server and choice firmware the use of HP SUM on HP Proliant ML10 v2.
This is an optionally available alternative you can do, before putting in home windows server 2012 R2 on your HP Proliant ML10 V2 server. Once HP Service Pack for ProLiant (SPP) is load with the aid of your server, you can pick two option to replace the firmware on P Proliant ML10 V2 server, that options are Automatic Firmware Update Version 2015.10.0 and Interactive Firmware Update Version 2015.10.0. For beginner person, we recommended which you pick out Automatic Firmware Update Version 2015.10.Zero. Ok, now comply with this education below to replace server and choice firmware the use of HP SUM on HP Proliant ML10 v2.
Guide to replace the firmware.
- Make positive you have blank DVD media or USB flash disk.
- Then you ought to d0wnload HP Service Pack for Proliant or SPP. From Here
//h17007.Www1.Hp.Com/us/en/company/servers/merchandise/service_pack/spp/index.Aspxor Here.//blog.Diploma.No/2015/04/hp-provider-percent-for-proliantspp-whilst-you-dont-have-care-p.C./This is a massive document, for the modern-day version (2015.10.Zero) has five.12 GB length. - Once down load complete, switch this document to USB flash disk, and make it bootable stick.
- You can read this guide to make Bootable USB flash disk the use of the HP USB key software for windows.
- Make sure you have changed boot order on HP Proliant ML10 v2 server , in addition from USB flash disk.
- Once your server boot up to load your flash disk, you may see two alternatives should you pick.
- Automatic Firmware Update Version 2015.10..0
- Interactive Firmware Update Version 2015.10.Zero
- Now you should choose Interactive Firmware Update Version 2015.10.Zero than enter.
- Wait for this system to load.
HP provider Pack ProLiant - load program - Then you'll see this on your screen.
HP carrier PAck ProLiant - load program - Now application will ask to pick your language, through default it in English. Then click on on Accept to just accept the End User License Agreement (EULA)
EULA - select language - Then click on next to continue.
HP service PAck Proliant - Then you may see this photo in your screen, to start update server and alternative firmware using HP SUM on HP Proliant ML10 v2, you need to click on on Firmware Update. This will update server and option firmware the usage of HP SUM.
- Now you will see this display screen, just anticipate the update firmware technique run.
firmware update the use of HP SUM. - Now application will replace the stock of baseline and node. Once end click Next
firmware update the usage of HP SUM - replace inventory - On the subsequent window, you may see step 2.
firmware update the usage of HP SUM - replace inventory - Now, scroll down this window and click on Deploy
firmware update the use of HP SUM - deploy - Now, you may enter step 3, this is the remaining step to update the firmware on HP Proliant ML10 v2. Simply watch for the final procedure to set up.
firmware update the use of HP SUM - deploy - Once end, click reboot
firmware update the use of HP SUM - deploy - Now you can click Yes, Reboot on reboot confirmation
- Finish, your HP Proliant ML10 v2 will reboot now, and you've got been successfully updated server and option firmware using HP SUM.